Three-circuit Time Relay
VL-100А, VL-101А


VL-100А, VL-101А - three-circuit time relay

VL-100А, VL-101А

Three-circuit time relay has instantaneous, passing and finite contacts. Such a kind of device is used with the time excerpts (delays) after giving (VL-100A) and after turning off the supply voltage (VL-101A).

The time relays (VL-100A, VL-101A) are intended for switching of electrical circuits with certain time excerpts, that are beforehand set in the protection devices, emergency control systems and industrial automatic equipment.

  • Working temperature: - 40 °С … + 55 °С.
  • Unified linkage and connection dimensions for the convenience of the relay mounting and service.
  • The mounting with front / back wires connection.
  • Step control of the actuation settings with discretization of 1% of the maximum value.
  • For visual control and operative change relay actuation unitshave a transparent cover with a possibility of sealing.
  • LED indication of the output relay actuation.

Working conditions

Closed housing in areas with a temperate and frigid climate.
Shaking effect:
- in the range of the frequencies of (5-15) Hz with an acceleration of 3 g;
- in the range of frequencies to 60 Hz with an acceleration of 2 g;
- in the range of frequencies to 100 Hz with an acceleration of 1 g;
- repeated blows by duration (2-20) ms with acceleration of 3 g.
Working position in the space – any.


Functional charts of work:


VL-100А - function diagram                     VL-101А - function diagram


Technical characteristics

Power supply, input VL-100А VL-101А
Voltage supply, V Direct current 24, 110, 220 110, 220
Alternating current 100, 220, 380* 100, 220, 380*
Allowable limits of the voltage supply from 0,8 to 1,1 Urated
Actuation voltage, V (0,65-0,75) Urated (0,65-0,75) Urated
Reset voltage, V (0,4-0,5) Urated (0,4-0,5) Urated
Power consumption, W (VA), not more than 6 10
Output
Quantity of the circuits 3 3
Quantity of the change-over contacts
(including * contacts of the instant action)
1* + 1 + 1 1* + 1 + 1
The range of the time settings уставок (according to modifications), s 0,05-4,95
0,1-9,9
0,3-29,7
1-99
0,05-4,95
0,1-9,9
0,2-19,8
Excerpt control by step
Minimum time of repeated readiness, s 0,1 0,1-0,3
Reset time, s 0,08 Seton a scale
Switching voltage, V
(direct and alternating current with frequency of 50 Hz)
from 24 to 250
Switching currents, А from 0,01 to 2
Switching power, VA(W)
- in the circuit of alternating current
- in the circuit of direct current

300 VA at cosπ=0,5
60 W at τ=0,05 s and 30 Wт at τ=0,02 s
Mechanical durability, cycles 106 105

Electrical endurance makes up 50 000 cycles; off-load - 100 000 cycles.

Relays VL-100A, VL-101A are installed by means of projection mounting with front/back wires connection.



VL-100А, VL-101А - wiring diagram
VL-100А, VL-101А - connection circuit


VL-100А, VL-101А - outside and linkage dimensions
Outside and linkage dimensions VL-100A, VL-101A